2DIN+2AIN+2DO Industrial Remote IO Module M100 T/E

Quick Info

Industrial Remote IO Module M100 is designed for IIOT applications and Industrial Automation, it compatible with MQTT Protocol, Modbus RTU Protocol, Modbus TCP Protocol, equip with 2DI, 2DO, 2AI.
  • T Version: 1*RJ45+1RS485+2DIN+2AIN+2DO
  • E Version: 2*RJ45+1RS485+2DIN+2AIN+2DO
  • T Version: 1*RJ45+1RS485+2DIN+2AIN+2DO
  • E Version: 2*RJ45+1RS485+2DIN+2AIN+2DO
Industrial Remote IO Module M100 is designed for IIOT applications and Industrial Automation, it compatible with MQTT Protocol, Modbus RTU Protocol, Modbus TCP Protocol, equip with 2DI, 2DO, 2AI.

Industrial Remote IO Module M100 provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs.

 

At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.

Industrial Remote IO Module M100 Provides 2 optical-isolated digital inputs, supports Max. 10MHz high speed pulse counter, 2 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 2 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.
Industrial Remote IO Module M100 can work at wide working voltage range, the range is 12 ~ 36VDC with anti-reverse protection design. Also, it provides 1 channel 12~36VDC power output for external device to save wiring cost.














1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection;
3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP,MQTT protocol;
5. 2 optical isolated digital input, supports Max. 700KHz high speed pulse counter;
6. 2 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
7. 2 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
8. High sampling frequency and special filtering strategy to ensure reliability;
9. 1 RS485 Serial port, supports Modbus RTU Master and slave, can extend I/O modules;
10.Supports register mapping function and extend I/O inquiry strategy;
11.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;
12.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
13.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
14.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.

Ethernet Remote I/O Module Specifications

• Digital Input

Sensor Type

Wet Contact (NPN or PNP), Dry Contact

I/O Mode

DI or Event Counter

Dry Contact

• On: short to GND=0
• Off: open=1

Wet Contact (DI to COM)

• On: 10 to 30 VDC =1
• Off: 0 to 3 VDC=0

Counter Frequency

700khz(Only the 1st Channel can be used as high speed pulse counter)

Digital sampling frequency

500Hz

Digital filtering strategy

Continues 3 times

Isolation

Optical Isolated,3k VDC or 2k Vrms

• Digital Output

Type

Sink

I/O Mode

DO

Pulse Output Frequency

10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs)

Over-Voltage Protection

50 VDC

Over-Temperature Shutdown

175°C (typical), 150°C (min.)

Load Current

 Max. 500 mA per channel

Digital sampling frequency

500Hz

• Analog Input

Type

Differential input

Resolution

12 bits

I/O Mode

Voltage / Current (jumper selectable)

Input Range

0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C

Sampling frequency

20Hz

Isolation

Electrical isolation

• Working Power Requirements

Input Voltage

12 to 36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

Input Current

139 mA @ 24 VDC

• Power Output

Output Voltage

12 to 36 VDC

Output Current

139 mA @ 24 VDC

• LAN

Ethernet

10/100 Mbps, RJ45 ports

Protection

15KV ESD Protection

Protocols

Modbus TCP, TCP/IP,TCP Server,TCP Client

Max. TCP Connection

5

• Serial Port

RS485

MODBUS- RTU Protocol, Modbus-ASCII Protocol, Modbus Master or slave.

Protection

15KV ESD Protection

Modbus Slave address

1~255

Baud Rate

1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

Mapping registers

Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

• Physical Characteristics

Wiring

I/O cable max. 14 AWG

Dimensions

105 x 88 x 30 mm

Weight

Under 205 g

Mounting

DIN rail or wall

• Environmental Limits

Operating Temperature

Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

5 to 95% (non-condensing)

Altitude

Up to 3000 m

Typically applications:

1.      BTS Monitoring;

2.      Security Alarm System applications;

3.      Supervision and monitoring alarm systems;

4.      Automatic monitoring system;

5.      Vending Machines security protection;

6.      Pumping Stations, Tanks, Oil or Water levels;

7.      Buildings and Real Estate;

8.      Weather Stations;

9.      River Monitoring and Flood Control;

10.   Oil and gas pipelines;

11.   Corrosion protection

12.   Temperatures, water leakage applications;

13.   Wellheads, boat, vehicle;

14.   Energy saving, street lights control system;

15.   Valve controls;

16.   Transformer stations;

17.   Unmanned machine rooms;

18.   Control room application;

19.   Automation System, M2M;

20.   Access Control System;

21.  PLC Gateway, PLC Remote Monitoring.