4CH Analog Data Acquisition Module(4 AIN input)DAM116
Quick Info
The DAM116 remote data acquisition module is designed for industrial automation measurement systems,uses high-precision AD acquisition and data processing technology, professional MCU controller, nonlinear processing algorithm, high precision

The DAM116 remote data acquisition module is designed for harsh industrial applications and is used in a wide range of industrial automation measurement,for measuring 4 channel analog input(0-5V,0-10V,0-20mA,4-20mA) ,and can transmit in ASCII data format to any RTU, SCADA, data monitoring, data loggers, PLC’s, process controllers and instrumentation that supports Modbus RTU Protocol over RS485 serial port. Powered up by 9~36VDC.
4 analog inputs, which can measure 4~20mA, 0-20mA, 0-10V or 0~5V signals from transmitter, current, voltage, pressure, temperature and power. 1 RS485 supports standard MODBUS-RTU communication protocol.
The DAM series remote data acquisition module can also be used as an expansion module of GSM 3G 4G RTUS27x, which can greatly expand the number of I/O ports of S27x to meet the needs of different applications.
1.Standard Modbus-RTU, good compatibility and easy programming;
2.ESD Protection circuit for RS485 serial port;
3.Wide range power supply with reverse polarity connection protection;
4.Built-in watchdog ensure it reliability;
5.Lightning protection ensure it stability;
6.12-bit resolution high precision AD acquisition and data processing techniques;
7.4 Analog inputs,default: 4~20mA, 12 Bits ,Isolated;Optional:0~20mA/4~20mA/0-5V/0~10V;
8.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
9.Small size, L110 * W84 * H30mm, compatible wall installation and DIN35mm industrial rail installation.
Item | Specifications |
DC Power supply | 9-36VDC(Peak Voltage must≤40V) |
Power consumption | Typically≤3W |
Communication Protocol | Modbus RTU |
Modbus Address | 1-247 |
Data format | n,8,1;e,8,1;o,8,1 or n,8,2 |
Communication interface | RS485 |
Baud rate | 1200,2400,4800, 9600, 19200, 38400Bps |
Analog inputs | 4,default is 4-20mA,Optional:0~20mA/4~20mA/0-5V/0~10V |
Thermometer Wires | Default: 2 Wires; Optional: 3 Wires. |
Measurement Precision | ±0.1%FS |
Withstand Tests | Output /Shell: 2000VAC/min.; 500VDC>100 MΩ |
Installation Type | Wall mount or 35mm DIN Rail |
Operation Temperature | -20~70℃ |
Relative Humidity | -40~85℃ |
Size | 110×84×30mm mm(HxWxD) |
AI Remote IO Module used as extend IO in IOT Applications