8DIN+8AIN+8DO Ethernet Remote IO Module M160

Quick Info

The M160T/E Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 10Mhz high speed pulse counter, 8 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 8 digital outputs.
  • T Version: 1*RJ45+1RS485+8DI+8DO+8AI
  • E Version: 2*RJ45+1RS485+8DI+8DO+8AI

Modbus MQTT Ethernet Remote I/O Module M160T/E is an industrial class, isolated designed, high reliability, high stability, and high precision data acquisition module, embedded 32-Bit High-Performance Microprocessor MCU, Integrated 1/2 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is designed for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring systems, automatic measurement, and control systems.

The M160T Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.
The M160T Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 700Khz high speed pulse counter, 8 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 8 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.

1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Power supply 12~36VDC with over voltage and phase-reversal protection;
3. Supports TCP Server, TCP Client, Modbus TCP, MQTT Protocols;

4. DO1 support PWM output;

5. Integrated 1~2 Industrial 10/100M adaptive Ethernet module inside;

6. 8 optical isolated digital input, supports max. 700khz high speed pulse counter;
7. 8 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
8. 8 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
9. High sampling frequency and special filtering strategy to ensure reliability;
10.1 RS485 Serial port, supports Modbus RTU Master or Slave, can extend I/O modules;
11.Supports register mapping function and extend I/O inquiry strategy;
12.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;
13.LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
14.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
13.Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.

Ethernet Remote I/O Module Specifications

• Digital Input
Sensor TypeWet Contact (NPN or PNP), Dry Contact
I/O ModeDI or Event Counter
Dry Contact• On: short to GND=1
• Off: open=0
Wet Contact (DI to COM)• On: 10 to 30 VDC=1
• Off: 0 to 3 VDC=0
Counter FrequencyMax. 700kHz(Only the 1st Channel can be used as high speed pulse counter)
Digital sampling frequency500Hz
Digital filtering strategyContinues 3 times
IsolationOptical Isolated,3k VDC or 2k Vrms
• Digital Output
TypeSink
I/O ModeDO or Pulse Output
Pulse Output Frequency10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs)
Over-Voltage Protection50 VDC
Over-Temperature Shutdown175°C (typical), 150°C (min.)
Load CurrentMax. 500 mA per channel
Digital sampling frequency500Hz
• Analog Input
TypeDifferential input
Resolution12 bits
I/O ModeVoltage / Current (jumper selectable)
Input Range0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA
Accuracy±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C
Sampling frequency20Hz
Built-in Resistor for Current Input162 ohms
IsolationElectrical isolation
• Working Power Requirements
Input Voltage12~36 VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;
Input Current139 mA @ 24 VDC
• Power Output
Output Voltage12~36 VDC
Output Current139 mA @ 24 VDC
• LAN
Ethernet10/100 Mbps, RJ45 ports
Protection15KV ESD Protection
ProtocolsModbus TCP, TCP/IP,MQTT,TCP Server, TCP Client
Max. TCP Connection5
• Serial Port
RS485MODBUS- RTU Protocol, Modbus-ASCII Protocol
Protection15KV ESD Protection
Modbus Slave address1~255
Baud Rate1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;
Mapping registersBit Type: 300 Registers, 16-Bit Type: 300 Registers.
• Physical Characteristics
WiringI/O cable max. 14 AWG
Dimensions105 x 88 x 30 mm
WeightUnder 205 g
MountingDIN rail or wall
• Environmental Limits
Operating TemperatureStandard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
AltitudeUp to 3000 m